10
GasAlertMicroClip XT
Technical Reference Guide
Pushbutton
Table 5. Pushbutton
Pushbutton Description
C
To activate the detector press C.
To deactivate the detector, press and hold C until the OFF countdown is complete and the LCD
deactivates.
To view the TWA, STEL, and peak (maximum) readings, press C twice. To clear the TWA, STEL,
and peak readings, press C when the LCD displays RESET.
To initiate calibration, deactivate the detector. Press and hold C while the detector performs the
OFF countdown. Continue holding C while the LCD briefly deactivates. The LCD reactivates and
then begins the CAL countdown. Release C when the CAL countdown is complete.
To activate the backlight in normal operation, press C.
To acknowledge latched alarms, press C.
To acknowledge a low alarm and disable the audible alarm, press C (if the Low Alarm Acknowl-
edge option is enabled).